Descrizione Azione
Codice: FY-EH4246
Dettagli
Codice: FY-EH2981
Dettagli
Codice: FY-EH3434
Dettagli
Codice: FY-EH4866
Dettagli
Codice: FY-EH1714
Dettagli
Codice: FY-EH4174
Dettagli
Codice: FY-EH4214
Dettagli
Codice: FY-EH4175
Dettagli
Codice: FY-EH4281
Dettagli

This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human CSTA. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CSTA and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CSTA, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human CSTA. You can calculate the concentration of Human CSTA in the samples by comparing the RLU value of the samples to the standard curve.

Codice: E-CL-H0139_96T Confezionamento: 96T
Dettagli

This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human CSTA. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CSTA and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CSTA, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human CSTA. You can calculate the concentration of Human CSTA in the samples by comparing the RLU value of the samples to the standard curve.

Codice: E-CL-H0139_48T Confezionamento: 48T
Dettagli

This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human CSTA. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CSTA and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CSTA, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human CSTA. You can calculate the concentration of Human CSTA in the samples by comparing the RLU value of the samples to the standard curve.

Codice: E-CL-H0139_24T Confezionamento: 24T
Dettagli